Akutan
Community water system in Akutan, Aleutians East Borough, Alaska, serving 95 people from surface water. 10 rules violated in the past three years. Owned by tribal government.
Quarterly compliance history
2023
2023
2024
2024
2024
2024
2025
2025
2025
2025
2026
2026
2026
Rules violated in the past three years
Jul to Sep 2023 to Jul to Sep 2026
Revised Total Coliform Rule
Monitoring Violation
20 violations, Jul 2023 to Jun 2026
Revised Total Coliform Rule
Monitoring Violation20 violations, Jul 2023 to Jun 2026
Monitoring Violation: 20 violations, Jul 2023 to Jun 2026. The system did not complete required monitoring. This does not show that a contaminant was found.
What the rule requires: The 2013 RTCR (effective 2016) replaced the original TCR. It triggers automatic E. coli testing whenever total coliform is found. A single E. coli-positive sample is an acute MCL violation. It also requires systems exceeding 5% total coliform-positive samples to conduct a formal assessment and correct any deficiencies, helping prevent contamination before it escalates.
About this rule
Interim and Long Term 1 Enhanced Surface Water Treatment Rule
Monitoring and Reporting
8 violations, Oct 2023 to May 2026 · Interim Enhanced Surface Water Treatment Rule
Interim and Long Term 1 Enhanced Surface Water Treatment Rule
Monitoring and Reporting8 violations, Oct 2023 to May 2026 · Interim Enhanced Surface Water Treatment Rule
Monitoring and Reporting: 8 violations, Oct 2023 to May 2026. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
Contaminant on the record: Interim Enhanced Surface Water Treatment Rule.
Long Term 2 Enhanced Surface Water Treatment Rule
Monitoring and Reporting
11 violations, Jul 2023 to Sep 2024 · E. coli (Escherichia coli)
Long Term 2 Enhanced Surface Water Treatment Rule
Monitoring and Reporting11 violations, Jul 2023 to Sep 2024 · E. coli (Escherichia coli)
Monitoring and Reporting: 11 violations, Jul 2023 to Sep 2024. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
Contaminant on the record: E. coli (Escherichia coli).
Surface Water Treatment Rule
Monitoring and ReportingTreatment Technique Violation
Health-based
23 violations, Jul 2023 to May 2026
Surface Water Treatment Rule
Monitoring and ReportingTreatment Technique Violation Health-based23 violations, Jul 2023 to May 2026
Treatment Technique Violation, health-based: 1 violation, May 2024 to Jun 2024. The system did not carry out a required treatment process or corrective action.
Monitoring and Reporting: 22 violations, Jul 2023 to May 2026. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
What the rule requires: All systems using surface water (rivers, lakes, reservoirs) or groundwater under surface influence (GWUDI) must filter and disinfect. Treatment technique violations mean the system failed to maintain adequate disinfectant residual, exceeded turbidity limits, or lacked required permits. Snowmelt and storm events can raise turbidity and pathogen loads in surface water.
Health effects: Without proper filtration/disinfection: Giardia lamblia (severe diarrhea, cramping), Cryptosporidium (life-threatening for immunocompromised individuals), viruses (hepatitis A, norovirus). Turbidity itself is not a health risk but can shield pathogens from disinfection. Limit: Treatment technique: turbidity ≤0.3 NTU in 95% of monthly samples; detectable disinfectant residual in 95% of distribution samples
About this rule
Stage 1 Disinfectants and Disinfection Byproducts Rule
Monitoring and Reporting
17 violations, Jul 2023 to Jun 2026 · Chlorine (MRDL)
Stage 1 Disinfectants and Disinfection Byproducts Rule
Monitoring and Reporting17 violations, Jul 2023 to Jun 2026 · Chlorine (MRDL)
Monitoring and Reporting: 17 violations, Jul 2023 to Jun 2026. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
Contaminant on the record: Chlorine (MRDL).
Stage 2 Disinfectants and Disinfection Byproducts Rule
Monitoring and Reporting
4 violations, Jan 2023 to Dec 2025 · 2 contaminants
Stage 2 Disinfectants and Disinfection Byproducts Rule
Monitoring and Reporting4 violations, Jan 2023 to Dec 2025 · 2 contaminants
Monitoring and Reporting: 4 violations, Jan 2023 to Dec 2025. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
Contaminants on the record: Total Haloacetic Acids (HAA5), TTHM (Total Trihalomethanes).
Volatile Organic Chemicals
Monitoring and Reporting
42 violations, Jan 2023 to May 2026 · 21 contaminants
Volatile Organic Chemicals
Monitoring and Reporting42 violations, Jan 2023 to May 2026 · 21 contaminants
Monitoring and Reporting: 42 violations, Jan 2023 to May 2026. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
Contaminants on the record: 1,2,4-Trichlorobenzene, cis-1,2-Dichloroethylene, Xylenes, Total, Dichloromethane (Methylene Chloride), o-Dichlorobenzene, p-Dichlorobenzene, Vinyl Chloride, 1,1-Dichloroethylene, trans-1,2-Dichloroethylene, 1,2-Dichloroethane, 1,1,1-Trichloroethane, Carbon Tetrachloride, 1,2-Dichloropropane, Trichloroethylene (TCE), 1,1,2-Trichloroethane, Tetrachloroethylene (PCE), Chlorobenzene, Benzene, Toluene, Ethylbenzene, Styrene.
Nitrate Rule
Monitoring and Reporting
2 violations, Jan 2023 to May 2026
Nitrate Rule
Monitoring and Reporting2 violations, Jan 2023 to May 2026
Monitoring and Reporting: 2 violations, Jan 2023 to May 2026. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
What the rule requires: Nitrate (NO₃) is the most common chemical contaminant in US groundwater, entering from fertilizers, septic systems, and animal waste. It is odorless and tasteless — the only way to know if it's present is to test.
About this rule
Lead and Copper Rule
Monitoring and Reporting
1 violation, Jan 2026 to May 2026
Lead and Copper Rule
Monitoring and Reporting1 violation, Jan 2026 to May 2026
Monitoring and Reporting: 1 violation, Jan 2026 to May 2026. The system did not complete required monitoring, or did not report the results on time. This does not show that a contaminant was found.
What the rule requires: The 1991 LCR uses action levels rather than MCLs: if the 90th percentile of high-risk tap samples exceeds 15 ppb lead or 1.3 mg/L copper, the system must take escalating corrective actions. Violations typically indicate failure to maintain adequate corrosion control — the treatment that keeps lead from leaching out of pipes, solder, and fixtures.
About this rule
Consumer Confidence Rule
Other Violation
3 violations, Jul 2023 to Mar 2026
Consumer Confidence Rule
Other Violation3 violations, Jul 2023 to Mar 2026
Other Violation: 3 violations, Jul 2023 to Mar 2026. A requirement other than monitoring, reporting, or a contaminant limit, such as public notice or the annual water quality report.
What the rule requires: Community water systems must deliver an annual water quality report (Consumer Confidence Report) to all customers by July 1, covering the previous year. It must list all detected contaminants, compare them to MCLs, identify source water, and include educational language about lead. A violation means the report was not delivered on time or was incomplete.
About this ruleLead and copper at the tap
The 90th percentile of the tap samples the system collected in its latest monitoring period, against EPA's action level. Levels vary between homes.
Action level 0.015 mg/L · Jan 2021 to Dec 2023
About this data
Rules violated and the list above come from EPA's SDWIS violation records, one row per violation and contaminant, grouped by the rule each row belongs to. A violation counts when its non-compliance period ended on or after Jul 1, 2023, the start of the thirteen quarters ECHO's three-year figures cover, or is still open; it is unresolved when it was still open at EPA's data refresh on Oct 7, 2026. EPA's rule code 500, "Not Regulated", is left out, as in ECHO's counts. Each rule's violation count is EPA's, and one rule can carry several: a missed monitoring round for a group of contaminants is one violation per contaminant and period. Category names are EPA's violation categories.
ECHO's own summary count of rules violated agrees with this grouping for 98.8% of active systems nationally, and its count of rules being violated for 98.7%; where they differ, the figures here follow the rows listed.
A measured value shown with a rule is the sample result EPA recorded with that violation (SDWIS viol_measure), against the limit EPA recorded on the same row (state_mcl), both in EPA's unit as written; violations without a recorded value, such as missed monitoring, show none. Other measured contaminant levels are not part of this record; each system publishes them in its annual Consumer Confidence Report.
Lead and copper are the newest 90th-percentile results in EPA's SDWA data download (LCR_SAMPLES, codes PB90 and CU90): for each monitoring period a system reports the 90th-percentile value of its tap samples, which EPA compares with its action level of 0.015 mg/L for lead and 1.3 mg/L for copper (40 CFR 141.80). A result is not a measurement of any one tap.
Service area from EPA's Public Water System Service Area Boundaries dataset: State. The system's location is the centre of the service area EPA publishes for the system.
Source: the U.S. EPA's Enforcement and Compliance History Online system (ECHO), which publishes the federal Safe Drinking Water Information System. EPA's terms and values are shown as published. The Alaska records are from EPA's data refresh of Oct 7, 2026; EPA refreshes this data quarterly, and states report to EPA with a lag of three to six months, so the newest violations may not appear yet.